![Meler Micron PUR LC Скачать руководство пользователя страница 82](http://html1.mh-extra.com/html/meler/micron-pur-lc/micron-pur-lc_instruction-manual_1767109082.webp)
MELER GLUING SOLUTIONS
5-8
MAINTENANCE
0.01µm
5µm
purga automática
purga automática
Recommended lubricants
BRAND
TYPE OF OIL
IP
Telesia Compound A
SHELL
Tivela Compound A
MOBIL
Glygoyle Grease 00
Safety Thermostat
If there is a deactivation of the thermostat, dismantle the tank casing with the
cover and slide the electrical cabinet along. When you can see the thermostat,
press the button indicated to reset it.
Air dryer filter maintenance
The filtering elements prior to the air dryer device on the melting equipment
are equipped with a filter saturation indicator, which indicates the best time to
change the filter cartrtidge:
- Green colour:
Low level of cartridge contamination.
- Red colour:
The cartridge is contaminated. Replace immediately,
otherwise equipment performance cannot be guaranteed.
We recommend installing new cartridges once a year, regardless of the
indicator reading (differential pressure).
Follow these steps to change the cartridge:
- Close the air valve.
- Release the drainage hose from the reservoir, if connected.
- Slowly turn the knurled screw clockwise. This will purge the air from
the filter.
- Push the reservoir towards the head of the filter.
- Slowly turn the reservoir clockwise as far as possible (1/8 of a turn)
and remove it, pulling down.
- Remove the cartridge and replace it with a new one (do not touch the
filter screen with your hands).
- Mount the reservoir, following these instructions in reverse order.
- Pressurize the filter, opening the by-pass valve slowly.
Warning
: It is necessary to keep the power connected to the unit in order to
keep the air dryer system operational. The system may operate even with cold
adhesive, in order to keep the internal environment moisture-free.
Содержание Micron PUR LC
Страница 1: ...ADHESIVE MELTER MICRON PUR LC MC INSTRUCTIONS MANUAL MA 5184 GBR 010920 GLUING SOLUTIONS ...
Страница 20: ...This page is intentionally left blank MELER GLUING SOLUTIONS 2 8 INTRODUCTION ...
Страница 34: ...MELER GLUING SOLUTIONS INSTALLATION 3 14 This page is intentionally left blank ...
Страница 49: ...MELTER OPERATION 4 15 MA 5184 ENG MICRON PUR LC MC ADHESIVE MELTER This page is intentionally left blank ...
Страница 84: ...MELER GLUING SOLUTIONS 5 10 MAINTENANCE Esta página no contiene texto ...
Страница 90: ...MELER GLUING SOLUTIONS 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 94: ...MELER GLUING SOLUTIONS 9 2 SPARE PARTS LIST This page is intentionally left blank ...