4-27
MELTER OPERATION
MA-5127-ENG
MACRO FOAM SERIES MELTER MANUAL
Loader OFF function
If you want to disable the automatic pellet feeder, push and hold the OFF
button for 3 seconds. The warning light will start to flash slowly. If you want to
activate loading, push the lit “RESET” button and loading will be reactivated.
OFF mode resets all existing alarms (if it goes into OFF mode with the open lid
alarm activated, when loading is activated and if the lid is still open it will wait
the programmed time to activate the open lid alarm).
Colourless warning light
If the equipment has the warning light optional feature, the colourless warning
light statuses are as follows:
1. OFF: the equipment’s level is high enough.
2. Steady on: the equipment is loading (EV= ON)
3. Very slow flashing: load blocked status
4. Fast flashing: error status.
Low level detection
Launching the feeder
Stopping the feeder
System refilled
Detection of the correct level
Start of the over-level timing