MELTER OPERATION
MA-5127-ENG
MACRO FOAM SERIES MELTER MANUAL
Keeping the ‘Vin’ key pressed will show the voltage sent by the main machine.
The pump will stop whenever:
• The control card is disabled with its ON/OFF button.
• The pumping ON-OFF button is pressed (red LED is illuminated).
• When the MAXIMUM PRESSURE ALARM TIME appears.
• When the MINIMUM PRESSURE ALARM TIME appears.
• When the voltage signal from the main machine is zero.
The maximum full scale for admissible pressure is 85 bar.
This full scale can be adjusted by reducing this value in percentage terms.
To make adjustments consult the ‘User configuration menu’, ‘1. MAXIMUM
PRESSURE ALARM’.
Mode of operation with external pumping control and internal pressure
control
In this operating mode, pumping is controlled from the main machine while
pressure is controlled from the equipment.
Follow the pressure below to use this operating mode:
1. Press the ON/OFF button to light up the control card.
2. Select ‘ok’ in the position ‘ext’ and ‘ref’ in the position ‘int’. The ‘on ext’
LED will be illuminated when temperature is ok.
To activate the start-up status, all of the following conditions must be met:
• That the input for pumping permission (E4) at central control is activated, as
pumping is not possible unless the equipment temperature is OK.
• That pumping is enabled with the pumping ON-OFF button (red LED is
turned off).
• If the external ‘ok’ mode (start-stop) is selected, the external ‘ok’ input
(E3) must be activated.
• That the failure input is not activated (E5), in which case starting the
pump would be impossible. In case of the pump be operating and this
input is activated, pumping will cease immediately.
Содержание MACRO FOAM Series
Страница 1: ...MA 5127 ENG 231220 GLUING SOLUTIONS ADHESIVE MELTER MACRO FOAM SERIES INSTRUCTIONS MANUAL ...
Страница 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 34: ...FOCKE MELER GLUING SOLUTIONS S A 3 14 INSTALLATION This page is intentionally left blank ...
Страница 75: ...ELECTRICAL DRAWINGS 7 1 MA 5127 ENG MACRO FOAM SERIES MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Страница 76: ...FOCKE MELER GLUING SOLUTIONS S A 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 78: ...FOCKE MELER GLUING SOLUTIONS S A 8 2 PNEUMATIC DIAGRAMS This page is intentionally left blank ...