FOCKE MELER GLUING SOLUTIONS, S.A.
3-10
INSTALLATION
3. Connect the two wires from the start-up signal to the terminals XLD1
and XLD2. This is a double terminal, which makes it necessary to
connect each wire in one of the two holes in the terminal. Since this
contact is not under voltage, there is no connection polarity.
4. Make sure that the cables are firmly attached by the terminal screws.
5. Make sure that the cable is well connected and that its path through
the electrical cabinet presents no risks of snagging, being cut or any
other accidental deterioration.
Warning:
It must be connected to 24 AC or DC voltage. If you connect this
signal to 230V load current cannot be less than 50mA.
Output inhibitor
1. If this is the only signal being connected, use a seven-wire cable no
smaller than 0.22 mm
2
.
2. Open the door to the electrical cabinet as far as possible. Thread the
power cord (Ø4-8 mm) through the electrical wall bushing Pg13 and
fasten it to the inside anchor, making sure that the cord reaches the
power card connector at the position where it will be installed.
3. Remove the connector from the card and connect the two cable wires
to their corresponding connector terminals:
1 voltage output
2 input for inhibitor output 1
3 input for inhibitor output 2
4 input for inhibitor output 3
5 input for inhibitor output 4
6 input for inhibitor output 5
7 input for inhibitor output 6
8 without connection.
4. Reconnect the card connector.
5. Make sure that the cable is well connected and that its path through
the electrical cabinet presents no risks of snagging, being cut or any
other accidental deterioration.
It is possible to select the channels that you want to control from the outside
using the small switches located above the connecter. Switches 1 through 6
control each of the channels, so that the switch in the ‘ON’ position means
heating from the equipment, without any external control.
When the switch is in the ‘OFF’ position, the corresponding channel does not
heat unless activated from the outside, through a non-voltage contact between
pin 1 (the common pin) and the pin that corresponds to the channel.
1 2 3 4 5 6 7 8
Pg13
XV12
XV22
XP12 XP22
XE12 XE22
XT0K2
XLD2
8X82
17X12
XX00
XV11 XV21 XP11
XP21
XE11 XE21
XT0K1
XLD1
8X81
17X11
Содержание MACRO FOAM Series
Страница 1: ...MA 5127 ENG 231220 GLUING SOLUTIONS ADHESIVE MELTER MACRO FOAM SERIES INSTRUCTIONS MANUAL ...
Страница 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 34: ...FOCKE MELER GLUING SOLUTIONS S A 3 14 INSTALLATION This page is intentionally left blank ...
Страница 75: ...ELECTRICAL DRAWINGS 7 1 MA 5127 ENG MACRO FOAM SERIES MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Страница 76: ...FOCKE MELER GLUING SOLUTIONS S A 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 78: ...FOCKE MELER GLUING SOLUTIONS S A 8 2 PNEUMATIC DIAGRAMS This page is intentionally left blank ...