FOCKE MELER GLUING SOLUTIONS, S.A.
4-24
MELTER OPERATION
By default the table is programmed (0 V = 0 bar and 10 V = 85 bar):
Notes on the editable values in the conversion table:
• The value for voltage must always be shown to one decimal place.
• Point 1 is the starting point for the
pressure curve, and therefore
the voltage will always be 0, while the value for output PRESSURE is
editable.
• The possible values for each point must be equal to or greater than the
value corresponding to the previous point.
• Point 5 is the final point for the pressure curve, and therefore the
voltage will always be 10, while the value for output PRESSURE is
editable.
• It is not necessary to program the value for MAXIMUM PRESSURE in this
table.
• If, at any point, the maximum value for Vin = 10 V is entered, the
corresponding values for Vin and PRESSURE at higher points will be
automatically updated according to the value for this point.
• If, at any point, the maximum value is entered, that is, PRESSURE (bar)
= MAXIMUM PRESSURE, the corresponding values for PRESSURE at
higher points will be automatically updated to MAXIMUM PRESSURE.
VViinn
PPrreessssuurree
(bar)
ppooiinntt 11
0,0
0
ppooiinntt 22
2,5
25
ppooiinntt 33
10,0
80
ppooiinntt 44
10,0
80
ppooiinntt 55
10,0
80
0
10
20
30
40
50
60
70
80
90
100
0,0
2,5
10,0
10,0
10,0
PPrreessssuurree
Pressure (bar)
VViinn
PPrreessssuurree
(bar)
ppooiinntt 11
0,0
0
ppooiinntt 22
10,0
85
ppooiinntt 33
10,0
85
ppooiinntt 44
10,0
85
ppooiinntt 55
10,0
85
0
10
20
30
40
50
60
70
80
90
100
0
10
PPrreessssuurree
Pressure (bar)
Содержание MACRO FOAM Series
Страница 1: ...MA 5127 ENG 231220 GLUING SOLUTIONS ADHESIVE MELTER MACRO FOAM SERIES INSTRUCTIONS MANUAL ...
Страница 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 34: ...FOCKE MELER GLUING SOLUTIONS S A 3 14 INSTALLATION This page is intentionally left blank ...
Страница 75: ...ELECTRICAL DRAWINGS 7 1 MA 5127 ENG MACRO FOAM SERIES MELTER MANUAL 7 ELECTRICAL DRAWINGS ...
Страница 76: ...FOCKE MELER GLUING SOLUTIONS S A 7 2 ELECTRICAL DRAWINGS This page is intentionally left blank ...
Страница 78: ...FOCKE MELER GLUING SOLUTIONS S A 8 2 PNEUMATIC DIAGRAMS This page is intentionally left blank ...