INSTALLATION
3-13
MA-5127-ENG
MACRO FOAM SERIES MELTER MANUAL
External adhesive feeder
1. If this is the only signal being connected, use 0.5 mm
2
two-wire cable.
2. Thread the power cord (max. Ø12.5 mm) through the electrical wall
bushing Pg13 and fasten it to the inside anchor, making sure that the
cord reaches the power card connector.
3. Connect the two wires from the external adhesive feeder order signal
to the terminals 17X11 and 17X12. This is a double terminal, which
makes it necessary to connect each wire in one of the two holes in the
terminal. Since this contact is not under voltage, there is no connection
polarity.
4. Make sure that the cables are firmly attached by the terminal screws.
Warning:
It must be connected to 24 AC or DC voltage with a maximum
current of 1A.
Pg13
XV12
XV22
XP12 XP22
XE12 XE22
XT0K2
XLD2
8X82
17X12
XX00
XV11 XV21 XP11
XP21
XE11 XE21
XT0K1
XLD1
8X81
17X11