4-25
MELTER OPERATION
MA-5127-ENG
MACRO FOAM SERIES MELTER MANUAL
Programming pressure curve
To access this menu and program the different points corresponding to the voltage-
pressure ratio, you must select external reference (‘ref ext’ LED is illuminated) and
press the right arrow key. Then the following message is displayed:
The IN LED to the position
ON
and the OUT LED to the position
OFF, 1 000,
NOT EDITABLE;
press the right arrow to go to the next point:
The IN LED to the position
OFF
and the OUT LED to the position
ON, 1 XXX,
which means that the output pressure is being programmed for point 1
(when the input voltage is 0 V); with the up/down arrow keys the value may be
modified, within a range from 000 to MAXIMUM PRESSURE; press the right
arrow key to go to the next point:
The IN LED to the position
ON
and the OUT LED to the position
OFF, 2 XXX
,
which means that the input voltage value is being programmed for point 2; with
the up/down arrow keys the value may be modified, within a range from 00.0 to
10.0 (to one decimal place); press the right arrow key to go to the next point:
The IN LED to the position
OFF
and the OUT LED to the position
ON, 2 XXX,
which means that the output pressure value is being programmed for point 2;
with the up/down arrow keys the value may be modified, within a range from
000 to MAXIMUM PRESSURE; press the right arrow key to go to the next point:
The IN LED to the position
ON
and the OUT LED to the position
OFF, 3 XXX
,
which means that the input voltage value is being programmed for point 3; with
the up/down arrow keys the value may be modified, within a range from 00.0 to
10.0 (to one decimal place); press the right arrow key to go to the next point:
The IN LED to the position
OFF
and the OUT LED to the position
ON, 3 XXX,
which means that the output pressure value is being programmed for point 3;
with the up/down arrow keys the value may be modified, within a range from
000 to MAXIMUM PRESSURE; press the right arrow key to go to the next point:
The IN LED to the position
ON
and the OUT LED to the position
OFF, 4 XXX,
which means that the input voltage value is being programmed for point 4; with
the up/down arrow keys the value may be modified, within a range from 00.0 to
10.0 (to one decimal place); press the right arrow key to go to the next point:
The IN LED to the position
OFF
and the OUT LED to the position
ON, 4 XXX,
which means that the output pressure value is being programmed for point 4;
with the up/down arrow keys the value may be modified, within a range from
000 to MAXIMUM PRESSURE; press the right arrow key to go to the next point:
The IN LED to the position
ON
and the OUT LED to the position
OFF, 5 100,
NOT EDITABLE; press the right arrow key to go to the following message:
The IN LED to the position
OFF
and the OUT LED to the position
ON, 5 XXX,
which means that the pressure value is being programmed for point 5; with
the up/down arrow keys the value may be modified, within a range from 000 to
MAXIMUM PRESSURE; press the right arrow key to exit the menu.
Press the right arrow key to return to the menu, and the initial message is
displayed: The IN LED to the position
ON
and the OUT LED to the position
ON, 1 000.
To exit this menu, the equipment must be turned off and started up using the
control card ON/OFF button.
To save the newly entered data, use the right and left arrow keys to go forward
or backward in the menu: if any field has been modified using the up/down
arrow keys, and the ON/ OFF button is pressed to turn the equipment off, the
data will not be saved.
Содержание MACRO FOAM Series
Страница 1: ...MA 5127 ENG 231220 GLUING SOLUTIONS ADHESIVE MELTER MACRO FOAM SERIES INSTRUCTIONS MANUAL ...
Страница 8: ...FOCKE MELER GLUING SOLUTIONS TABLE OF CONTENTS This page is intentionally left blank ...
Страница 34: ...FOCKE MELER GLUING SOLUTIONS S A 3 14 INSTALLATION This page is intentionally left blank ...