Description of product
4.4.3
Single/dual lane feedback control with light control and automatic
closing
Function:
1.
Opening the gate system after activation taking the safety equipment into con-
sideration.
2.
Closing the gate system once the hold open time and if necessary the pre-
warning time has lapsed taking the safety equipment into consideration.
3.
Light control depending on the occurrence of signals at the inputs for impulse
inside, impulse outside or two channel radio.
Details:
•
impulse inside
•
impulse outside
•
in / - key
Activation
from either:
•
radio
triggers the following function: the gate opens.
The direction of travel is approved using lights depending on gate control activation
(triggering from inside or outside). In the event of alternating activation (triggering
from inside or outside) within the hold open time, the direction of travel is changed
over using the lights after a pre-warning time which may be set if necessary.
The gate shuts automatically once the “hold open” time and if necessary the pre-
warning time has lapsed.
Note
If selected, the superordinate special operating mode of
continuously open
(clock) is undertaken in preference to the single/dual lane feedback control with
light control.
4.4.4
Special operating modes:
4.4.4.1 Manual mode
Function:
Opening and closing the gate system taking the safety equipment into considera-
tion.
Details:
The gate opens or closes for as long as the in or – keys are pressed.
Note
This mode is used for start-up as well as other functions.