4 - 12
Gate control operating manual mts2000/02
Description of product
4.7 Technical
data
4.7.1
Electrical data
4.7.1.1 Mains
connection
Voltage supply
230 VAC
(at terminals 43, 44)
PE (protective conductor)
230 V AC
Block of terminals on housing base
Power consumption
<15 W
4.7.1.2 Stop
switch
Stop switch
24 V AC/ 1 A
(terminals 1, 2)
Halt key
24 V AC/ 1 A
(terminals 3, 4)
4.7.1.3 Impulse sensor connections
Open key or inside impulse
24 V / 100 mA
(key, potential-free contact at terminals 5, 6)
Close key or outside impulse
24 V / 100 mA
(key, potential-free contact at terminals 7, 8)
Key for impulse sequence or switch
for continuously open (external clock) 24 V / 100 mA
(key, potential-free contact at terminals 9, 10)
The line length of the impulse sensor should not exceed 15 m. Longer lines must
if necessary be disconnected (e.g. potential-free activation of connection via a
relay contact).
4.7.1.4 Interfaces for safety equipment
Closing edge protection
12 V / 8.2 k
Ω
optical (OSE)
terminals 11, 12, 13
electro-mechanical (EMC)
terminals 11, 12
Stop in closed position
(light barrier, potential-free contact)
24 V / 100 mA
Supply for transmitter
terminals 16,17
Supply for receiver
terminals 16,17
Switching output
terminals 14,15