10
Setting the Required Air Pressure
There is a pressure relief regulator valve inside the TakClean control box. Adjusting this valve will change the force that engages
the adhesive rolls.
This valve will have been set at Meech before your system was supplied, so that the bottom adhesive roll engages the bottom
TransTak elastomer roller with the required level of force.
CAUTION
If you need to adjust the pressure relief valve, make sure that it is not adjusted to provide maximum pressure between the
adhesive roll and TransTak elastomer roller. If too high a pressure is used, it may result in damage to the adhesive roll and
TransTak roller, or effect the web path during operation.
TakClean Button Functions
Auto/Manual Button
Engage/Disengage Button
The Auto/Manual Button toggles between auto mode and manual mode. The Engage/Disengage button will not function when in
Auto Mode and the Auto/Manual button is illuminated. When in Auto Mode the TakClean is engaged/disengaged when receiving
the remote On/Off signal from the line.
The Engage/Disengage Button will engage and disengage the adhesive rolls when set in manual mode.
Compressed Air Circuit
Please view the drawing section at the end of this manual for a circuit diagram.