17
2. Remove the lid from the top of the positive compartment, when the lid is removed the nozzle splitter box will be
in the middle of the positive compartment.
3. Each individual nozzle is numbered, this number corresponds to the numbering in the splitter box. To remove
a nozzle first you need to take note of the number you would like to change. Then the cables can be removed
from the splitters by loosening the grub screws in the splitters. The cable gland will also need to be loosened so
the cables can be removed.
Both positive and negative cables will need to be removed for the nozzle to change location. The lid has a splitter
sheet which shows where the cables are located.