Features
Display
In normal operation the LCD display will look similar to the following:
The information displayed is:
1.
Power:
Peak momentary output voltage in kV. This value is controlled automatically and will increase
and decrease as the system maintains maximum performance.
2. Rate:
Frequency of the output in Hz. The output frequency is
operator set according to the type of installation and the
ionising equipment connected to the 977CM.
3.
Balance:
Balance of the Positive and Negative outputs in Percent. The balance can be biased to
positive or negative to give the most accurate neutralisation.
4. Ion Output:
Graphical display of system performance with percentage value.
Controls
Four buttons control the 977CM:
Up:
Moves the cursor up and increases numerical values
Menu: Enters and exits the main system menu
Down: Moves the cursor down and decreases numerical values
Tick: Accepts and stores the displayed value