31
Operation
Getting Started
On first use, the 977CM needs to be configured to suit the type of application. This includes basic settings of the
Rate and Balance as well as alarm functionality and the lock option.
Setting the Rate
The 977CM features a variable output frequency. The frequency that should be set depends on the distance to the
target object.
For best operation at long distance a slow rate should be set. Conversely at short range, select a fast rate. An
approximate guide is as follows:
25
20 20
15
10
5
5
1
0
0.5
100 150 200 250 300 350 400 450 500 550 600
Operating Distance (mm)
Fr
eque
ncy Ra
te
(Hz)
Suggested Frequency Vs Operating Distance for 977CM
To set the rate
1. Press
to enter menu
2. Use
and
to select option 2 “Rate”
3. Use
and
to set the required value.
4. Press
to accept value.
52% Positive/ 48% Negative