44
Maintenance
Maintenance (UK Specific)
It is a legal requirement, under regulation 9 of the COSHH regulations, that all local exhaust ventilation systems are
visually inspected on a weekly basis where possible, and undergo a thorough inspection and test on an annual basis.
COSHH requires the annual inspection and testing to be carried out by a competent person with a specific
documentation of the results held in a log book.
General Maintenance
User maintenance is limited to cleaning the IonWash™ and replacing the filters with new. Only trained maintenance
technicians are authorised to carry out component testing and replacement.
Unauthorised work or the use of unauthorised replacement filters may result in a potentially dangerous situation
and/or damage to the IonWash™, and will invalidate the manufacturer’s warranty.
Cleaning the IonWash
Do not use abrasive cleaning product as this will damage the finish. The IonWash™ should be cleaned with a
proprietary surface cleaner, following the manufacturer’s instructions.
The cooling inlets and outlet should be cleaned at least quarterly to prevent build-up of dust and overheating of
unit.
Main Maintenance areas
Positive compartment
At the rear of the IonWash there is a cover plate for the positive and cooling compartments. This cover can be
removed to ensure there is not a build-up of any type of contamination in these areas. This should be checked every
2 months.
There should be no contamination in this area as the air is filtered that runs through the pumps. If there is
contamination in the positive or cooling sections then Meech should be contacted immediately before any damage
is done.