Nozzle Installation
The nozzles will be located as requested when the IonWash was ordered, this will be dependent on the component
that is being cleaned.
IonWash is supplied with 16 nozzles. However there is the ability for the nozzles to be located in 40 different
positions. The location and angle of the nozzles will depend on the component shape.
If after testing it is found that the nozzles need to be relocated, please follow the below relocation guide. If for any
reason 16 nozzles are not required then they can be blanked off and less nozzles used. The maximum number of
nozzles is 20.
How to relocate or remove the nozzles
The nozzles should be located as requested at the point of order. However, if for any reason they need to be moved
then the following guide will help with the relocation.
Note: this should only be done by a trained engineer or under supervision from a Meech Engineer or Distributor.
CAUTION: before changing the nozzle location, Turn off the supply to the electrical supply to the IonWash.
1. Remove the top access panel (8 screws) at the top on the front of the IonWash, this does not have to be done if
the engineer is able to work at height.