4.12 Air function
The air function includes the logic for querying window contacts. To use the air function, this has to
be activated in the parameters of the channel.
The following figure shows the corresponding submenu:
Figure 20: Parameter - Air function
The table below shows the available settings:
ETS-Text
Dynamic range
[default value]
Comment
Window contacts
1 contact for
„
open window
2 contacts for
„ope
/
tilted i do
Setting whether one or two
window contacts are installed
1 contact:
Value for
„
open
Value 0
Value 1
Sets the value for open windows
2 contacts:
Value for
„
open
contact 1 = 0, contact 2 = 0
contact 1 = 1, contact 2 = 0
contact 1 = 0, contact 2 = 1
contact 1 = 1, contact 2 = 1
Sets the value for open windows
Value for „
tilted
contact 1 = 0, contact 2 = 0
contact 1 = 1, contact 2 = 0
contact 1 = 0, contact 2 = 1
contact 1 = 1, contact 2 = 1
Sets the value for tilted windows