Technical Manual Shutter Actuator JAL-0X10X.02
MDT technologies GmbH •
51766 Engelskirchen • Papiermühle 1
Tel.: +49-2263-
880 • Fax: +49
-2263-4588
• [email protected] • www.mdt.de
55
55
An example of using the block function is to block the blinds/shutters when opening a terrace door.
Thus, e.g. when opening the terrace door, the blinds/shutters are moved upwards and are blocked.
The following table shows the corresponding communication object:
Number
Function
Length
Usage
45
Block
1 Bit
Activation/deactivation of the simple blocking function
Table 26: Communication object - Block
4.10.5 Move to hight position
For each channel, an absolute height position can be set, which is approached by the setting "move
to height position":
ETS-Text
Dynamic range
[default value]
Comment
Height position for
alarms/blocking
0-100%
[0%]
Setting the absolute height position
for alarms/blocking. Can be adjusted
when set to "shutter"
Blind position for
alarms/blocking
0-100%
[0%]
Setting the absolute height position
for alarms/blocking. Can be adjusted
when set to "blinds
Slat position for
alarms/blocking
0-100%
[0%]
Setting the absolute slat position for
alarms/blocking. Can be adjusted
when set to "
li ds
Table 27: Setting options - Move to hight position
An absolute height position can be defined per channel,which can be approached with an active
alarm or an active block. This position is valid for all alarms of this channel