60
13-CLEANING
SHUTDOWN (end of season)
At the end of each season, before switching the product off, it is recommended to remove all the pellets from the tank with a vacuum
cleaner with a long pipe.
We recommend removing the unused pellet from the tank because it can retain humidity. Disconnect any combustion air ducting that
can lead humidity inside the combustion chamber but, above all, ask the specialised technician to refresh the paint inside the combustion
chamber with the special silicone spray paints (available at any store or CAT) during the necessary annual end of season scheduled
maintenance operations. In this way the paint will protect the inner parts of the combustion chamber, blocking any type of oxidative
process.
When not in use the appliance must be disconnected from the mains power supply. It is recommended to remove the
power cable for additional safety, especially in the presence of children.
The service fuse may have to be replaced if the control panel display does not switch on when the product is switched on again by pressing
the main switch on its side.
There is a fusebox on the side of the product, near the power socket. Open the fusebox cover with a screwdriver and replace the fuses if
necessary (3.15 A delayed) - seek assistance from an authorised and qualified technician.
CHECKING THE INTERNAL COMPONENTS
ATTENTION!
The internal electromechanical components must only be checked by qualified personnel whose technical expertise
includes combustion and electricity.
We recommend that an annual maintenance service is carried out (with a scheduled service contract). This service is essentially a visual
and functional inspection of the internal components. The following is a summary of the checks and/or maintenance that are essential for
the correct operation of the product.
PARTS/INTERVAL
1 DAY
2-3 DAYS
30 DAYS
1 YEAR
Brazier
·
Ash compartment
·
Glass
·
Lower exchanger
·
Complete exchanger
·
Smoke duct
·
Door gasket
·
Remote control battery
(if purchased/optional)
·
Door closure operation
·