51
11-ALARMS
Technical Dept. - All rights reserved - Reproduction is prohibited
Exiting the alarm conditions
To reset the alarm, hold the ON/OFF button down for a while: the stove will check to see whether the cause of the alarm is still present or
not. In the first case, the alarm displays again, in the second case it turns OFF.
The product can be switched on again only after the cause of the fault has been definitively eliminated.
Normal shut down (panel display: shutdown)
When the shutdown key is pressed, or when there is an alarm signal, the stove enters the thermal extinguishing phase which involves
automatic execution of the following phases.
• pellet loading stops
• the room fan keeps running at the set speed so that the fumes temperature reaches 100°C, then runs at minimum speed until the
shut down temperature is reached.
• The smoke extractor fan is is activated at maximum speed and remains on for a fixed period of 10 minutes, at the end of which if
the smoke T has dropped below 45°C (displayed in the INFO menu), the fan stops, otherwise it will continue to operate at minimum
speed until the temperature drops below the threshold, and then stops.
POWER FAILURE WITH STOVE ON (panel display: ACCENSIONE DOPO BLACKOUT (STARTUP AFTER POWER FAILURE)
for 10’, then ACCENSIONE (STARTUP))
In the event of a power failure, the stove does the following:
• Power failure of less than 10”: continues the work in progress;
• After a loss of power of more than 10’’ which occurred when the stove was on, or during ignition, you can restore the stove to its
previous operating condition when power returns as follows:
• 1 - Cool the system by activating the smoke extractor at minimum speed for 10’ then proceed to the next step;
• 2 - Restore the stove to the operating condition prior to the power failure.
During phase 1, the panel shows ACCENSIONE DOPO BLACKOUT (STARTUP AFTER POWER FAILURE).
During phase 2, the panel shows ACCENSIONE (STARTUP).
If during phase 1-2 the stove receives manual user commands from the control panel or remote control, it stops the blackout restoration
sequence and begins the start-up or shutdown commanded by the user.
If the stove experiences a loss of power greater than 10’’ while it is shutting down, when power is restored to the stove, it will automatically
turn on in shutdown mode, even if the smoke temperature has fallen below 45°C in the meantime. This phase can be skipped by pressing
key 0/1 (skips to start-up) and pressing it again (recognises that the stove is off).
SAFETY ALARM A05
The safety alarm includes operation of the smoke pressure switch, of the open fuel loading door and stove door.
The time between the fumes pressure switch tripping and the alarm signal is 30 seconds, after which the stove is stopped (e.g. after 30
seconds with the pellet loading hatch open, alarm A05 is tripped).