C
A
B
A
B
o
y
D
n
y
55
13-CLEANING
Technical Dept. - All rights reserved - Reproduction is prohibited
PERIODIC CLEANING PERFORMED BY A QUALIFIED TECHNICIAN
CLEANING THE HEAT EXCHANGER
Half-way through the winter season,
but especially at the end
, the compartment through which the exhaust smoke passes will need
to be cleaned. This cleaning process is mandatory in order to facilitate the general removal of all combustion residue, before it becomes
very difficult to remove it due to the humidity compacting it over time.
ATTENTION:
It is obligatory to have an authorised and skilled technician perform the periodic end-of-season cleaning in order to
replace any worn gaskets.
CLEANING THE LOWER COMPARTMENT
To clean the lower ash compartment, you must remove the top “
C
”, the side panels “
A
” and “
B
”, and the front panel “
D
”. Now loosen the
four screws“
y
”, remove the plate “
n
” and gasket “
o
”; use the nozzle of a vacuum cleaner to remove any ash and soot that may have built
up in the lower exchanger indicated by the arrow.
Before restoring cap “
n
” we recommend changing the gasket “
o
”.
LOWER COMPARTMENT
CLEANING