PAGE 39
PLATFORM RAISES INSTEAD OF FOLDING
1/4”
2.
Check the “E” Solenoid Valve Coil for power. Place
a screwdriver about 1/4” from the “E” Solenoid and
activate the “FOLD” function on the switch. If the
screwdriver is drawn to the energized solenoid and the
unit wants to Raise instead of Fold, the solenoid must
be repaired or replaced. If the “E” Valve is
not
energized during the “FOLD” operation of the switch,
check the electrical connections.
OLD STYLE PUMPS ONLY
“M” Valve
Motor Solenoid
“E” Valve
4-Way Valve
1.
Check the Pump Motor Solenoid
for 12 Volts of power from the
battery. If there is no power to the
Solenoid, check the Battery Cables
for damage, and the Battery for a
charge. The use of a Voltage Load
Tester is recommended. Replace or
recharge as needed.
USE VOLTAGE
LOAD TESTER
HERE
GREEN
WIRE
WHITE
WIRE
“M” Valve
Motor Solenoid
3.
Disconnect the Runner Switch electrical cable (4-Pin Connector), from the
Control Box and activate the “FOLD” switches mounted outside the vehicle. If
the platform folds, then the short is in the Runner Switch Cable. Repair or
replace the Harness.