11921
Slauson
A
ve.
Santa
Fe
Springs,
CA.
90670
(800)
227-41
16
FA
X
(888)
771-7713
PAGE 29
SWITCH AND HARNESS REPLACEMENT
INSTALLATION OF CONTACTS
Use the DT Removal Tool (P/N 260875),
to pry between the lip of the Locking Wedge
and the Connector Plug. Then twist, popping
the Wedge free. The Locking Wedge can now
be easily removed. Push the Socket Contacts
through the Rear Seal of the Connector Plug
until it snaps into a locked position. Place the
Locking Wedge back into the origional
position and push it against the Connector
Plug.
Slide the DT Removal Tool
(P/N 260875), into the center slot
of the Locking Wedge. Rotate the
Removal Tool to grab the Wedge
from the inside and pull out with a
sharp tug. The Locking Wedge
can now be easily removed. Push
the Socket Contacts through the
Rear Seal of the Connector Plug until it snaps into a locked position. Place
the Locking Wedge back into the origional position and push it against the
Connector Receptacle.
IMPORTANT!
When placing the Contacts into the plugs and receptacles, be sure
the wire colors will match the mating plug or receptacle wire colors.
SOCKET
CONTACTS
LOCKING
WEDGE PLUG
CONNECTOR
PLUG
REMOVAL TOOL
LOCKING
WEDGE
RECEPTACLE
PIN
CONTACTS
CONNECTOR
RECEPTACLE
REMOVAL
TOOL
REMOVAL OF CONTACTS
After removing the Locking
Wedge of either the Plug or the
Receptacle, insert the DT Removal
Tool between the Contacts and the
Locking Finger. Gently push the
Locking Finger away from the
Contact while pulling the Contact and
wire free from the rear.
LOCKING
FINGER
PIN
CONTACTS
SOCKET
CONTACTS
Содержание BMR-35
Страница 30: ...11921 Slauson Ave Santa Fe Springs CA 90670 800 227 4116 FAX 888 771 7713 PAGE 30 TROUBLESHOOTING...
Страница 40: ...11921 Slauson Ave Santa Fe Springs CA 90670 800 227 4116 FAX 888 771 7713 PAGE 40 TROUBLESHOOTING GRAVITY DOWN...
Страница 44: ...11921 Slauson Ave Santa Fe Springs CA 90670 800 227 4116 FAX 888 771 7713 PAGE 44 TROUBLESHOOTING POWER DOWN...
Страница 48: ......