PLATFORM WILL NOT RAISE, MOTOR WON’T RUN
1.
Check the Pump Motor
Solenoid for 12 Volts of
power from the battery. If
there is no power to the
Solenoid, check the
Battery Cables for
damage, and the Battery
for a charge. Replace or
recharge as needed.
2.
Check the Solenoids in the Pump
Box and Columns for power. With the
control switch activated in the “UP”
position, only the Pump Motor Solenoid
should be energized. If any other
Solenoid is energized while in the “UP”
mode, there is damaged or improper
wiring in the Solenoids, Control Box, or
Switches. Disconnect the Runner
Switch electrical cable (4-Pin
Connector), from the Control Box and
activate the “UP” switch mounted
outside the vehicle. If the platform
raises, then the short is in the Runner
Switch Cable.
3.
Check for structural damage to the liftgate. Visually inspect for improper
bending of structures that could prevent normal operation.
BATTERY CABLE
TERMINAL
PUMP MOTOR
SOLENOID
SCREWDRIVER WILL BE
MAGNETICALLY PULLED TO
AN ENERGIZED SOLENOID
1/4”
OLD STYLE
NEW STYLE