Hardware Reference
MCD EPOS 60 W
December 2011 Edition / document number 791272-04 / subject to change
maxon motor control
Different types of proximity switches
Figure 12: Digital input 1, 2, 3 ,4 external wiring examples
Use of 3-wire PNP proximity switches is preferred.
Use of 3-wire NPN proximity switches needs an additional
external pull-up resistor
R
ext
(12V) = 1 k
Ω
(150mW)
R
ext
(24V) = 5 k
Ω
(120mW)
Use of 2-wire proximity switches is possible.
Consider a minimal load current of approximately 5mA should be
complied. Depending on 2-wire proximity switch an additional
parallel resistor is necessary.