Hardware Reference
MCD EPOS 60 W
December 2011 Edition / document number 791272-04 / subject to change
maxon motor control
These opto-
isolated outputs are defined as “General Purpose” by default
and can be configured via software setting.
Digital output 3
[DigOUT3]
Connector [J1] Pin number [12]
Digital output 4
[DigOUT4]
Connector [J1] Pin number [13]
+V Opto IN
[+V Opto IN]
Connector [J1] Pin number [11]
Common signal
[IN_COM]
Connector [J1] Pin number [10]
Type of Output
Optical isolated
Open-Emitter
Output voltage
U
out
≥
(+V Opto IN
– 1.5V)
Max. load current
I
load
≤
350 mA
Leakage current
I
leak
≤
50
μA
Switching delay
< 300
μ
s @ 24 VDC
Max. inductive load
2 H @ 24VDC; 500mA
Figure 13: Digital output 3
Содержание MCD EPOS 60 W
Страница 1: ...maxon document number 791272 04...