Hardware Reference
MCD EPOS 60 W
December 2011 Edition / document number 791272-04 / subject to change
maxon motor control
Logic supply
voltage
[+V
C
12-50 VDC] Connector [J2] Pin number [8]
Ground of supply
voltage
[Power_Gnd]
Connector [J2] Pin number [5]
Optionally, the logic supply voltage can be sourced separately.
This
allows
a
safe
and
economical
power
backup
feature.
In case of no separate Logic supply is applied, the Logic supply will be
sourced by the Power supply voltage automatically.
Any available power supply can be used, provided it meets the minimal
requirements set out below.
Output voltage
V
C
min. 12 VDC; V
C
max. 50 VDC
Ripple
< 10 %
Min. Output power
P
C
min. 3 W
Содержание MCD EPOS 60 W
Страница 1: ...maxon document number 791272 04...