S p e c i f i c a t i o n s
Power Module DN
Version 09.2019
Page 38/43
10.4 Control signals
Interface signals maximal current load 100mA.
D-Sub15 PIN14/15: 0...10 VDC Output maximal current load 1mA.
Do not connect D-Sub interface to a PC verbinden. PC and power module may be
damaged.
D-Sub interfaces are potentially seperated and require 24VDC power supply
provided by the customer.
DN150
DN750-1850
Coil module monitoring M8
0…24 VDC, <100mA
Sensor connector M12
0…24 VDC, 200mA
0
…24 VDC, 100mA
D-Sub15 Control Interface
0…24 VDC, <100mA, PIN14/15: 0...10 VDC <1 mA
D-Sub09 power setting interface
0…24 VDC, <100mA
Table 14: Control Signals
10.4.1 Sensor connector M12
DN150
DN750-1850
Voltage range
0…24 VDC
Maximum current
100mA
Connector:
Device socket M12 4-pin Pole no. 4
Configuration
PIN
Type
Colour
Voltage
Role
1
Output
brown
24VDC
Light barrier 24V
2
Input
white
24VDC
Light barrier signal
3
Output
blue
24VDC
Light barrier 0V
4
-
black
24VDC
-
Figure 11: Configuration connector M12