I n s t a l l a t i o n
Power Module DN
Version 09.2019
Page 14/43
4.3 Mounting
Power module cabinet mounting:
•
Placing on fixed base (optional)
•
Wall-mount using 4 available mounting eyes
Figure 5: DN with base and wall-mounted
4.1 Connection to grid
4.1.1 DN150
Voltage, current and frequency ranges according to technical specification!
Phase-neutral connection:
For connection phase (L1) and neutral (N) and protective conductor (PE) are required
(1P/N/PE).
Phase-phase connection (US) (optional)
For connection two phases (L1/L2) and protective conductor (PE) are required (2P/PE).
Colour code supply connector DN150:
Labelling 1P/N/PE
Colours 1P/N/PE
Labelling 2P/PE
Colours 2P/PE
L1 (phase)
brown
L1 (phase)
black
N (neutral)
blue
L2 (phase)
black
PE (protective conductor)
green/yellow
PE (protective conductor)
green/yellow
Table 2: Colour code supply connector DN150
4.1.2 Power cable (DN150)
The DN150 can be connected to the grid with the provided power cable. If required, replace
cable to comply with local regulation.
Delivery worldwide: cable type (16A/250VAC) with safety plug (type E/F, CEE 7/7).
Delivery Switzerland: cable type (13A/250VAC) with safety plug (type J, SEV 1011).