4.4 Fan connector
•
Voltage range see appendix
•
Connector configuration and pin assignment according to circuit diagram
4.4.1 Fan connector DN150 (optional)
For 230 VAC cooling fan
4.4.2 Fan connector DN750-1850
For 24 VDC cooling fan
4.5 Control signals
Interface signals maximal current load 100mA
D-Sub15 PIN14/15: 0...10 VDC Output maximal current load 1mA.
Do not connect D-Sub interface to a PC verbinden. PC and power module may be
damaged.
4.5.1 Coil module monitoring M8
Connection of
Coil module monitoring M8
is required for operation.
The M8 monitoring cable is connected to the
Coil module monitoring M8
. It controls the coil
warning light and monitors the coil temperature. Connection is required to operate the machine.
•
Connector configuration and pin assignment according to circuit diagram
4.5.2 Sensor connector M12
The
Sensor connector M12
allows the connection of an external pulse trigger (light barrier,
capacitive sensor, ...). A suitable light barrier is available at Maurer Magnetic AG.
•
Voltage range see appendix
•
Connector configuration and pin assignment according to circuit diagram
4.5.3 D-Sub15 Control Interface
The 15 pin
D-Sub15 Control Interface
allows control and monitoring of the machine via 24 VDC
signals. Further information
•
More information in chapter Operation
•
Voltage range see appendix
•
Connector configuration and pin assignment according to circuit diagram
4.5.4 D-Sub9 power setting interface
(DN750…1850, optional)
The 9 pin
D-Sub9 power setting interface
allows setting power of the power level of the
machine via 24 VDC signals.
•
More information in chapter Operation
•
Voltage range see appendix
•