© 2017 Baker Hughes, a GE company, LLC. All rights reserved.
50
6
1
ESD_NEW_
DATA
3
No
No/Yes
No/No
New ESD
Data
available
A shutdown event
is stored in mem-
ory and has not
yet been archived
by ValVue ESD.
Connect ValVue
ESD and wait for
flag to self-clear.
This will indicate
that ValVue ESD
successfully
archived signa-
ture in its data-
base.
51
6
2
ESD_DATA_
ERROR
3
Yes
Yes/No
No/No
Saving
ESD data
error
Upon a safety trip
(shutdown), a
problem occurred
when storing
event in memory.
1- Clear the condi-
tion using ValVue
ESD or HART
®
Host.
2- If condition per-
sists, replace
device and report
problem at svi-
sup-
[email protected].
52
6
3
PST_FAILED
1
Yes
Yes/Yes
Yes/Yes
PST
Failed
PST could not
complete suc-
cessfully because
of:
1- Problem vent-
ing
2- PST pressure
value was
reached before
target travel
3- PST Time value
was reached
before target
travel
4- An ESD event
happened during
PST.
1- Verify that vent
is not clogged up.
Verify that there
are no Pneumatic
Train Integrity
Alarm present.
2- Confirm that
PST pressure set-
ting is not too
high. Run an
extended signa-
ture to confirm
proper PST Pres-
sure for desired
travel target.
3- Verify that vent
is not partially
clogged or that an
accessory is not
restricting air
exhaust. Increase
setting based on
PST Travel Rate
and PST travel.
4- None
53
6
4
PST_NEW_
DATA
3
No
No/Yes
No/No
PST New
Data
A PST Test is
stored in memory
and has not yet
been archived by
ValVue ESD.
Connect ValVue
ESD and wait for
the flag to
self-clear. This will
indicate that Val-
Vue ESD success-
fully archived
signature in its
database.
Table 13 SVI II ESD Fault Matrix (Continued)
Sequence
Byte
#
Bit
#
FAULT Name
Criticality
of Alarm
Auto-
mati-
cally
cleared
Can be
cleared/
Persists
across
resets
Non-
Mas-
kable/
Annunci-
ated
TEXT For
DD &
ValVue
ESD2
English
Probable Cause
English
Recommended
Action
Содержание SVI II ESD
Страница 4: ...This page intentionally left blank ...
Страница 10: ...This page intentionally left blank ...
Страница 14: ...This page intentionally left blank ...
Страница 100: ...This page intentionally left blank ...
Страница 120: ...This page intentionally left blank ...
Страница 126: ...This page intentionally left blank ...
Страница 160: ...This page intentionally left blank ...
Страница 194: ...This page intentionally left blank ...
Страница 200: ...This page intentionally left blank ...
Страница 204: ...This page intentionally left blank ...
Страница 206: ...This page intentionally left blank ...
Страница 208: ...This page intentionally left blank ...
Страница 216: ...This page intentionally left blank ...