2-33
Specifications
Operating Environment
Temperature Limits
Temperature range: 40°F (4°C) to 120°F (49°C).
Electrical Requirements
Any clean, regulated power source between 100 VAC and 230 VAC at 50 or
60 Hz. The controller and printhead power supply should be connected to
the same AC source.
Recommended Distances
A set of maximum-recommended distances between each system
component has been established to ensure good print quality. (See
Figure 2W.) The distance from the last printhead to the ink system, only
applies to VJ printheads. HR Series printheads use Series 2000 ink systems.
Figure 2W: Recommended Component Distances
COMP
ANY
ABC
Controller
Shaft Encoder
Photocell
Furthest Printhead
100.0' (30.5 m)
25" (63.5 cm
)
100.0'
(30.5 m)
38.0'
(11.6 m)
52.5' (16.0 m)
25.0' (8.0 m)
0.25" (0.6 cm)
Maximum
Throw Distance
ADS Ink System
Printhead Power
Supply
Note: Dimensions represent
maximum cable lengths,
not linear distances.