Troubleshooting
6-21
m. Disconnect the data lines and power supply cable from the
printhead.
n. Disconnect the syringe tubing from the outlet port.
o. Reconnect the outlet tubing to the outlet port.
p. Disconnect the valve tubing from the inlet port.
q. Reconnect the inlet tubing to the inlet port.
r. Repeat the above steps as necessary for additional valves.
10) Reinstall the printhead assembly in the printhead enclosure, and
reconnect the ground wire.
11) Reconnect the ink line, data lines and power supply cables to the
printhead.
12) Plug in the printhead power supply and the controller.
13) Purge the printhead, then run a test print. (See “Purging a VJ
14) Was good quality print achieved?
• Yes, reinstall the printhead cover and resume normal operations.
• No, repeat the valve backflushing procedure. If good quality print is
still not attained, see “Replacing a VJ Printhead Valve” on
page 7-10.
Figure 6F: Backflushing a Valve
Nozzle
Nozzle Tubing
Manifold Tubing
Ink Manifold
To Collection
Container
Valve
Valve Tubing
Printhead Assembly
Plunger
Small Syringe
Inlet Port
Outlet Port
(Center)