Table 2.1 Service
Connections
specifications and details
G
Gas Supply Connection
-
1/2" NPT
EC
Electrical Connection
-
120 VAC, 60hz, 1/2" conduit or equivalent.
Current draw for 120V control circuitry is 6.5
Amps. Use wire suitable for at least 90°C.
CW
Cold Water
-
1/2" NPT to cold water supply manifold. Cold
water supply line to have a maximum of 50 PSI
(3.5 kg/cm2) and a minimum of 25 PSI (1.8
kg/cm2) water pressure.
D
Drain
-
1 1/2" 0. D. pipe coupled to 1 1/2" 0. D.
tempering tank drain. DO NOT MAKE SOLID
CONNECTION TO FLOOR DRAIN.
F
Flue
-
Place unit so that the Flue is under an exhaust
hood to remove the products of gas combus -
tion. DO NOT TOUCH FLUE!
The Flue
reaches extremely high temperatures!
1.4 SERVICE CONNECTIONS
All service connections are made at the bottom of
the unit, in the 6 inch high space between the floor and
the bottom of the cabinet. Please see Figure 2.1 and
Table 2.1 for service connections, details and
dimensions.
NOTE:
If the equipment is to be installed where the
elevation exceeds 2,000 feet (609.6 meters) above
sea level, specify installation altitudes so that the
proper gas orifices can be provided.
MARKET FORGE INDUSTRIES, INC.
35 GARVEY STREET EVERETT, MA 02149
TEL: 617 387 4100 TELEX: 94-9414
2.3
PAX: 6 I 7 387 4456 OUTSIDE MA 800 227 2659
2. Installation