TROUBLE POSSIBLE CAUSE REMEDY
Generator continues to create
steam when the cooking
compartment door is opened.
1. Faulty magnet reed switch (contacts failed
closed).
2. Faulty wiring.
1. Check magnetic reed switch.
Replace if necessary.
2. Check wiring.
Tempering tank drain water
temperature too high.
1. Faulty 130°F thermostat in the tempering
tank.
2. Faulty tempering tank fill/cool solenoid valve.
3. Faulty wiring.
1. Check 130°F thermostat.
Replace if necessary.
2. If 120 Volt is verified at the solenoid
coil, but the valve fails to open, replace
solenoid.
3. Check wiring.
Generator doesn't drain when the
POWER Switch is pressed into the
OFF position.
1. Clogged or kinked generator drain line.
2. Clogged generator drain hole. 3. Faulty
generator solenoid drain valve.
1. Check to be sure that the generator
drain line is not kinked and is free of
debris.
2. Check to be sure the generator drain
hole is free of debris.
3. Rebuild or replace generator
solenoid drain valve.
Tempering tank doesn't drain when
both POWER Switches are in the
OFF position.
1. Clogged tempering tank drain line.
2. Clogged tempering tank drain hole.
3. Faulty tempering tank solenoid drain
valve.
1. Clean or replace tempering tank
drain line.
2. Check to be sure that the
tempering tank drain hole is free of
debris.
3. Rebuild or replace tempering tank
solenoid drain valve.
CLEAN GENERATOR light stays on
after it has been cleaned (delimed)
and rinsed.
1. Faulty or incorrectly set CLEAN
GENERATOR timer.
2. Faulty CLEAN GENERATOR relay.
3. Faulty wiring.
1. Check to be sure timer is set correctly.
Replace if necessary.
2.
Check/replace if necessary.
3. Check wiring.