TROUBLE POSSIBLE CAUSE REMEDY
Generator continuously creates
steam (Steam DEMAND light is
always on).
1. Cooking compartment door out of
alignment.
2. Cooking compartment door gasket leaky.
1. Check alignment of door.
Realign if necessary.
2. Check/replace door gasket.
3. Pressure switch disconnected.
3. Check to be sure all pressure switch
connections are made.
4. Faulty pressure switch (contacts failed closed).
4. Check/replace pressure switch.
5. Leaky cooking compartment drain line.
5. Check to be sure cooking
compartment drain line is sealed.
Replace if necessary.
6. Steam trap failed open.*
6. Check/replace steam trap.
7. Loss of water seal due to low water or no water
in tempering tank.*
7. See "Tempering tank will not fill"
section, on
page 5.1
of this manual.
Steam Suppression not
functioning. ( Excess steam
comes out of the cooking
compartment when the door is
opened.)
1. Dirty strainer screen in the spray nozzle
solenoid valve.
2. Dirt or lime accumulation in the generator
spray nozzle.
1. Clean or replace strainer
screen.
2. Clean generator spray nozzle.
3. Faulty timer which controls spray nozzle water
solenoid valve.
3. Check to be sure that timer is set
properly, and works. If it doesn't work,
replace it.
4. Misaligned ventilation ductwork.
4. Check ductwork and realign where
necessary.
5. Blower not running.
5. Check/replace fuse. Be sure that the
blower motor works.
If not, replace blower.
6. Faulty wiring.
6. Check wiring.
• If this is the problem, you will also notice excess amounts of steam coming out the vent tube at the top of the unit.