2.3 BEFORE USE
Before proceeding to Section 2.4, Service
Connections, be sure you have
road and under-
stand
the following statements.
•Keep this appliance free and dear from
combustibles.
• Do not obstruct the flow of combustion and
ventilation air.
•This installation, must conform with local codes,
or in the absence of local codes, with the
National Fuel Gas code, ANSI Z223.1, the
Natural Gas Installation Code.
For installation
in Canada, this appliance is to be in accor-
dance with the current
Natural Gas Installation
Code CAN/CGA-B149.1, or the Propane Gas
Installation Code. CAN/CGA-B149.2 .
and/ or
Local Codes as applicable, including:
•The generator and its individual shut off
valve must be
disconnected
from the gas
supply piping sys tem during any pressure
testing of that system at test pressure
in
excess
of 1/2 psig (3.45 k/PA).
•The generator must be
isolated
from the gas
supply system by closing its individual
manual shut off valve during any pressure
testing of the gas supply piping system at
test pressures
equal to or less than
1/2 psig
(3.45k/PA).
•This appliance, when installed, must be
electrically grounded in accordance with local
codes, or in the absence of local codes, with
the National
Electric code, ANSI/NFPA70-
Latest Edition.
For installation in Canada, all
electrical connections are to be made in
accordance with CSA C22. 1
Canadian
Electrical Code Part I
and/or Local Codes.
•This product must be installed in a room with
adequate air supply.
•Do not place any objects on or directly against
the unit that will block air openings into the
combustion chamber.
•Minimum clearances from both combustible and
non combustible surfaces are 2" (51 mm) from
right side wall, 2" (51 mm) from left wall and 6"
(152mm) from rear wall. Suitable for installation
on combustible floors.
•This unit is serviceable almost entirely from the
front. Do not install in such a manner that a
service person cannot access the lower front
cover panel. Some of the componentry may be
more easily accessed by removing either of the
side panels and/or the back panel, as shown in
Figure 6.1, on page 6.2 of this manual. The
minimum suggested clearance for servicing this
unit from the left or right sides is 18". The
minimum suggested clearance for servicing this
unit from the rear is 12"
The steps for side panel removal are as
follows:
1. To remove either side panel, remove the
screw from the center of the bottom edge of
the panel.
2. Slide the side panel upwards until it stops.
3. Swing the bottom edge of the s ide panel out
away from the unit far enough (about 1.5
inches), so that it is free to slide down to the
floor.
4. This will allow the top edge of the side panel
to slide out from under the top cap of the unit.
To remove the back panel, remove the 8 screws
which attach it to the unit, as shown in Figure
6.1, on page 6.2 of this manual
.
•There are no special lighting or shut down
procedures for the burners. Each burner is
controlled by the POWER, switch for that
generator.
• Keep this manual for daily reference.