8.5.6 E7 / EH / 0b (Indoor PCB / Display board communication error diagnosis and solution)
Description:
Indoor PCB does not receive feedback from the display board.
Recommended parts to check or to prepare:
• Communication wire
• Indoor PCB
• Display board
Troubleshooting and repair:
“Wall” Type Active Line R32 Refrigerant AC: 6. Troubleshooting
[6]-25
Troubleshooting and repair:
YES
NO
NO
YES
6.7.6 E7 / EH / 0b (Indoor PCB / Display board communication error diagnosis and solution)
Description
: Indoor PCB does not receive feedback from the display board.
Recommended parts to check or to prepare:
• Communication wire
• Indoor PCB
• Display board
Power
off, then restart the
unit
2
minutes later.
Is it still
displaying the
error code?
The unit functions normally.
Check the wirings and connections.
Ensure a proper connection.
Are all
the connections
good?
Replace the indoor main PCB.
Does
the error still
exist?
Replace the display board.