18
4.0 Product features
4.1 Display functions
Unit display functions (follow the display type of your purchased product):
fresh defrost run timer
fresh defrost run timer
fresh defrost run timer
Display
Function
fresh
or
Fresh (available on selected units only).
defrost
or
Defrost.
run
or
When the unit is on.
timer
or
When TIMER is on.
WiFi control (available on selected units only).
Temperature value
Temperature.
(3s)
(3s)
Activation of Timer ON, Fresh, Swing, Turbo, or Silent.
Cancellation of Timer OFF, Fresh, Swing, Turbo, or Silent.
Defrost.
Warming in heating mode.
Self-clean (available on selected units only).
Heating in room temperature under 8°C.
set temperature
gradually illuminates to
in 1 second
intervals.
ECO function (available on selected units only).
Note: Please select the display function according to your purchased product.
4.2 Safety features
Compressor 3-minute delay at restart
Compressor functions are delayed for up to 1 minute upon the first startup of the unit, and are delayed
for up to 3 minutes upon subsequent unit restarts.
Zero crossing detection error protection (except for DC fan units)
If AC cannot detect zero crossing signal for 4 minutes or the zero crossing signal time interval is not
correct, the unit will stop and the LED will display the failure. The correct zero crossing signal time
interval should be between 6-13ms.