54
8.5 Quick maintenance by error code
If you do not have the time to test whether specific parts are faulty, you can directly change the
required parts according to the error code. You can find the parts to replace by error code in the
following table.
Part requiring replacement
Error code
E0
E1
E2
E4
E4
E5
E7/Eb
EC
F0
EH 00
EL 01
EH 02
EH 03
EH 60
EH 61
EH 0B
EL 0C
PC 08
Indoor PCB
P
P
P
P
P
P
P
P
x
Outdoor PCB
x
P
x
x
x
x
x
x
P
Display board
x
x
x
x
x
x
P
x
x
Indoor fan motor
x
x
x
P
x
x
x
x
x
T1 sensor
x
x
x
x
P
x
x
x
x
T2 Sensor
x
x
x
x
x
P
x
P
x
Reactor
x
P
x
x
x
x
x
x
x
Compressor
x
x
x
x
x
x
x
x
P
Additional refrigerant
x
x
x
x
x
x
x
P
x
Part requiring replacement
Error code
F1
F2
F3
F4
F5
P0
P1
P2
P6
P4
EC 53
EC 52
EC 54
EC 51
EC 07
PC 00
PC 01
PC 02
PC 03
PC 04
Indoor PCB
x
x
x
x
x
x
x
x
x
x
Outdoor PCB
P
P
P
P
P
P
P
P
P
P
Indoor fan motor
x
x
x
x
x
x
x
x
x
x
Outdoor fan motor
x
x
x
x
P
P
x
P
x
P
T3 Sensor
x
P
x
x
x
x
x
x
x
x
T4 Sensor
P
x
x
x
x
x
x
x
x
x
TP Sensor
x
x
P
x
x
x
x
x
x
x
Reactor
x
x
x
x
x
x
P
x
x
x
Compressor
x
x
x
x
x
P
x
x
x
P
IPM module board
x
x
x
x
x
P
P
P
P
x
High pressure protector
x
x
x
x
x
x
x
P
x
x
Low pressure protector
x
x
x
x
x
x
x
x
P
x
Additional refrigerant
x
x
x
x
x
x
x
x
P
x
Note: For certain models, outdoor PCB could not be removed separately. In this case, the outdoor
electric control box should be replaced as a whole.
Содержание HCNI 533
Страница 1: ...MARK HEAT PUMP SPLIT UNIT 0662680 Technical manual EN...
Страница 2: ...2...
Страница 16: ...16 3 4 Outdoor Units Printed Circuit Board Diagram HCNMX 353 HCNI 533...
Страница 81: ...81 EN...
Страница 82: ...82...
Страница 83: ...83 EN...