1. Remote maintenance
Electrical Circuit
Refrigerant Circuit
Possible causes of trouble
Power failure
The main power tripped
Loose connections
Faulty transformer
The voltage is too high or too low
The remote control is powered off
Broken remote control
Dirty air filter
Dirty condenser fins
The seng temperature is higher/lower
than the room’s (cooling/heang)
The ambient temperature is too high/
low when the mode is cooling/heang
Fan mode
SILENCE funcon is acvated (oponal
funcon)
Frosng and defrosng frequently
Unit will not start
The power switch is on but fans will
not start
The temperature on the display board
cannot be set
Unit is on but the wind is not cold (hot)
Unit runs, but shortly stops
The unit starts up and stops frequently
Unit runs connuously but insufficient
cooling (heang)
Cool can not change to heat
Unit is noisy
Test method / remedy
Test voltage
Close the power switch
Inspect connectons - tighten
Change the transformer
Test voltage
Replace the battery of the remote
control
Replace the remote control
Clean or replace
Clean
Adjust the seng temperature
Turn the AC later
Adjust to cool mode
Turn off SILENCE funcon.
Turn the AC later