2.2 Technical data
Indoor unit model
HKEU 353
HKEU 533
Outdoor unit model
HCNMX 353
HCNI 533
Type
DC-Inverted heat pump
Control
Infra-red
Rated capacity (T=+35 °C)
Cooling
kW
3.52 (1.11~4.16)
5.28 (1.82~6.13)
Rated absorbed power (T=+35 °C)
KW
1.21 (0.13~1.58)
1.54 (0.14~2.36)
Rated energie efficiency coefficient
EER
2.91
3.43
Seasonal energy efficiency class
626/2011
A++
A++
Seasonal energy efficiency index
SEER
6.1
7.1
Annual energy consumption
kWh/a
221
256
Theoretical load (Pdesignc)
kW
3.60
5.20
Operating limits (outside temperature)
°C
-15~50
Rated capacity (T=+7 °C)
Heating
kW
3.81 (1.08~4.22)
5.57 (1.38~6.74)
Rated absorbed power (T=+7 °C)
kW
1.09 (0.10~1.68)
1.48 (0.20~2.41)
Rated energy performance coefficient
COP
3.50
3.76
Energy efficiency class (average season)
626/2011
A+
A+
Seasonal energy efficiency class index (average season)
SCOP
4.0
4.0
Annual energy consumption
kWh/a
945
1435
Theoretical load (Pdesignc) @-10 °C
kW
2.70
4.10
Operating limits (outside temperature)
°C
-15~30
Electrical data
Power supply
Outdoor unit
Ph-V-Hz
1Ph-220/240V-50Hz
Power cable
Type
3 x 2.5 mm
2
3 x 4 mm
2
Indoor and outdoor unit communication cable
Type
5 x 1.5 mm
2
5 x 1.5 mm
2
Refrigerant circuit
Refrigerant (GWP)
R32(675)
R32(675)
Diameter of refrigerant piping on liquid/gas
mm (inches)
Ø6.35(1/4”) - Ø9.52(3/8”)
Ø6.35(1/4”) - Ø12.74(1/2”)
Max splitting length
m
25
30
Max height difference I.U./O.U.
m
10
20
Split length without additional charge
m
5
5
Additional load
g/m
12
12
Indoor unit specifications
Net weight
Kg
7.6
10
Sound pressure level (I.U.)
Hi/Me/Lo
dB(A)
40.5/34.5/25
44/37/25
Sound power level (I.U.)
Hi
dB(A)
55
55
Treated air volume
Hi/Me/Lo
m
3
/h
540/430/314
840/680/540
Motor power (Output)
W
40
36
Outdoor unit specifications
Net weight
Kg
23.2
34
Sound pressure level (O.U.)
dB(A)
56
56
Sound power level (O.U.)
dB(A)
63
61
Treated air (Max)
m
3
/h
1800
2500
Motor power (Output)
W
63
63
2.3 Pipe length and drop height
The length and elevation of connection pipe are shown in the table below.
If the pipe length exceeds max. pipe length corresponding to refrigerant precharge, additional
refrigerant (R32) should be charged to ensure nominal cooling/heating capacity and prevent any
damages to the air conditioner.
Model
Standard
Length
Max Pipe
Length
Max Elevation
Additional R32
Charge
353
5m
25m
10m
12g/m
533
30m
20m
If oil flows back into the outdoor unit’s compressor, this might cause liquid compression or deterioration
of oil return. Oil traps in the rising gas pipe can prevent this.