Samplerate converter
23
The second row shows the status of the
samplerate-converter of the digital input. If the
green LED lights up in a column, the
samplerate-converter of this input is active and
functional. If the red LED lights up, the
samplerate-converts is active, though either no
clock can be captured from this input, or the
samplerate of this input differs in ration more
an 1:16/16:1 in reference to the clock
currently set up and active. If neither of control
LED is illuminated, the samplerate-converter of
this input is deactivated.
th
Z
If you have questions
concerning digital clock
and samplerate, please
read chapter „The
TRACE PRO AE in
connection with digital
devices”.
Z
The settings of the
samplerate-converter are
done via the settings
window of the TRACE
PRO AE manager.
The second row of the column “WC/SC IN”
features information about the
WordClock/Superclock input of the TRACE
PRO AE, if a clock can be extracted on this
input. It shows the frequency, which is coming
in on this input and the current setting of the
TRACE PRO AE manager as seen and set up in
“Synchronisation” under “WC/SC input”.