background image

The Advantage Series Installation

Page 18

MDE-3883 TRIND Retrofit Kits C00011-005

 • 10/00

 

PRELIMINARY

FCC 11/30

Re-installing Button 

1

Hold contact base on back of door and align with hole drilled earlier.

2

Insert push button from front of door by aligning tabs with slots in base.

3

Turn push button 45° clockwise to lock button to base. 

4

Tighten two screws on base to secure push button and base assembly to door.
Note: Do not overtighten screws.

5

Attach contact block to base with center screw if not already installed.

6

If unit does not have door alarm, reinstall all new right options door hardware 
except sheet metal shield by reversing procedures in Step 1 of “Modifying Right 
Options Door On Wide Frame Units” on page 16 and pr
oceed to “Installing 
Cables” on page 20.
 If unit has door alarm, proceed to “Re-installing Door Alarm 
Switches” on page 19.

S0001735

Push button

Contact switch 
base assembly

Base

Contact 
block

Содержание TRIND C00011-005 Series

Страница 1: ...interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instru...

Страница 2: ...nstall all TRIND Multi 1 kits Allen wrench set American standard clean cloth or rag chip extraction tool e g IC extraction Digikey Part No K158 ND or equivalent isopropyl alcohol part END 1082 needle...

Страница 3: ...le Group for All The Advantage Series Kits on page 3 cable tie Q10178 01 4 card cage assembly T20606 G3 see note 3 1 door assembly right options clear with TRIND T20613 G1 or T20613 G2 see note 1 1 pe...

Страница 4: ...options clear with TRIND T20614 G1 1 per side graphics right option door AD02002GN00X see note 2 grommet strip solid Q10315 01 1 5 ft jump jack Q11011 01 4 label plate FCC N23949 06 1 manual installa...

Страница 5: ...ommet strip solid Q10315 01 1 5 ft jump jack Q11011 01 4 kit MPD 3 parts K96646 05 see table below label plate FCC N23949 06 1 manual installation instructions MDE 3883 1 nut Q12068 03 2 screw phillip...

Страница 6: ...spensary devices and submerged turbine pumps STPs These you must operate in the event of an emergency Total Electrical Shut Off Before Access Any procedure requiring access to electrical components or...

Страница 7: ...and operation of the equipment Safety Symbols and Warning Words This section provides important information about warning symbols and boxes Alert Symbol This safety alert symbol is used in this manua...

Страница 8: ...fore you approach the dispenser island Prevent Electrical Shock and Sparks Dispensing devices use high voltage A potential shock hazard exists when working on or around a dispensing device Follow OSHA...

Страница 9: ...disturb sealing compound around wires at junction box entrances Use factory method of routing wires Use tie wraps to keep unruly wires away from pinch point and hinges Tuck wires into enclosure before...

Страница 10: ...aid assistance 6 Use approved and safe procedures to clean up all spills with a fuel or gasoline absorbent material approved by your local regulatory agencies Dispose of fuel and hazardous absorbent m...

Страница 11: ...o eye tissue Irrigate eyes with water for approximately 15 minutes Seek medical advice immediately Gasoline spilled on skin may cause burns Wash area thoroughly with clear water Seek medical advice im...

Страница 12: ...activate power while you are working on the equipment Use the OSHA tag out and lock out procedures discussed later in this section Contacting Emergency Personnel Keep the following emergency phone nu...

Страница 13: ...wn Breakaways Required by NFPA 30A breakaways are emergency devices designed to retain liquid on both sides of the breakaway point installed on each hose Refer to manufacturer s instructions for prope...

Страница 14: ...ction 514 Fuel is present Flammable Liquid Class 1 Division 2 Hazardous Location Class 1 Division 1 Hazardous Location Fuel Containing Components Vapor Areas 18 18 Unclassified location area within el...

Страница 15: ...for access instructions 3 Disconnect and remove existing hardware according to the following For wide frame units disconnect any cables and remove any call or stop buttons or door alarm switch hardwar...

Страница 16: ...s on page 19 For wide frame units with stop or call button previously installed on right options door do the following to relocate hardware to new T20613 G1 options door 1 Remove all hardware from new...

Страница 17: ...nter punch and hammer to mark placement of pump stop or call button hole on new right options door by measuring from door edges as shown below 3 Away from fuel island drill a 7 8 inch diameter hole in...

Страница 18: ...n base to secure push button and base assembly to door Note Do not overtighten screws 5 Attach contact block to base with center screw if not already installed 6 If unit does not have door alarm reins...

Страница 19: ...bracket with screw previously removed 4 Attach door alarm assembly bracket to display board with screw previously removed Note Replace the piece of fiberboard between door alarm bracket assembly and...

Страница 20: ...helf 2 Disconnect printer cable and pull cable out of 2 3 4 round hole from bottom and install piece of strip grommet Q10315 01 around perimeter of hole 3 Feed three prong end of power cable R20580 G1...

Страница 21: ...h holes in printer shelf For older units holes will not align with holes in shelf Remove both screws and save 4 Position rear of card cage on edge of cabinet shelf for easy cable connection Note Do no...

Страница 22: ...ge by doing the following Note While it is not necessary to remove printer to install card cage you may find your initial installations easier if this is done To do so disconnect two cables and remove...

Страница 23: ...ight options door according to the following steps 1 If sheet metal shield has not been previously removed using 1 4 nut driver remove sheet metal shield from back of door Refer to illustration in Mod...

Страница 24: ...cable at P1 J1 Note Card cage harness cables were positioned for installation in Step 7 of Installing Card Cage on page 21 5 Route B side harness cable with P2 connector through clamps above CRIND tr...

Страница 25: ...ide tip of knife or flat blade screwdriver under bottom edge of faceplate 4 Pry bottom of faceplate away from unit until faceplate can be removed from unit Dispose of faceplate For units with bolt on...

Страница 26: ...plate 5 With putty knife remove keypad door gasket and any adhesive residue Providing Cable Access into Main Cabinet 1 Open bezel doors on main cabinet 2 Locate indent on rear of door behind 3 4 diame...

Страница 27: ...s at bottom one each front and rear 2 Disconnect cables joining two sides of card cage 3 From A side of unit place bottom section of card cage fuse side first on to left shelf 4 Reassemble card cage u...

Страница 28: ...unit install screw up through hole under card cage Align screw with mounting hole on card cage but do not fasten Tilt card cage away from screw and secure screw to shelf by installing two nuts under c...

Страница 29: ...ace with keylock 5 Refer to MDE 2620 Graphics Panel Application for instructions on installing graphics For installing TRIND bolt on stud type faceplates do the following 1 Remove new TRIND faceplate...

Страница 30: ...sembly T20616 G2 securing in place from back side of bezel door using in this order 6 adhesive backed gaskets Q11659 01 Note Do not remove paper backing on adhesive side and install paper side to beze...

Страница 31: ...ibbon cable R20437 G01 connect J258A to P258 on A side CRIND Logic Board Note A side of split cable R20437 G01 has red wire 2 On ribbon cable R20437 G01 connect J258B to P258 on B side CRIND Logic Boa...

Страница 32: ...must have current Z 180 CRIND logic board Install the CRIND BIOS TRIND software K93744 XX one per logic board on the T17764 XX CRIND logic board s according to the following steps Note A properly gro...

Страница 33: ...17764 XX using a grounded chip removal tool 2 Install TRIND BIOS K93744 XX one per logic board at position U7 orienting notch on chip with indication mark on board as shown 3 Install jump jack on JP 1...

Страница 34: ...w these steps 1 From A side of unit locate dip switches on power supply board PCB T20314 G1 in card cage 2 Using switches 2 3 4 and 5 address each dispenser according to the following table Note Switc...

Страница 35: ...Gateway Board T20128 B Side JP14 JP15 JP16 JP17 JP18 1 IN OUT OUT OUT OUT 2 OUT IN OUT OUT OUT 3 IN IN OUT OUT OUT 4 OUT OUT IN OUT OUT 5 IN OUT IN OUT OUT 6 OUT IN IN OUT OUT 7 IN IN IN OUT OUT 8 OUT...

Страница 36: ...or less Light board should light and flash sequentially and emit one beep A screen prompt should appear Note If light does not function properly check to see if opposite side of unit was activated in...

Страница 37: ...R Y F C C 1 1 3 0 Cable Block Diagram Note Illustration assumes T20606 G3 Card Cage with wire harness that includes M00507A00X cables For T20606 G4 Card Cage a different harness is used but cables ha...

Страница 38: ...mmerce Systems Inc 7300 West Friendly Avenue Post Office Box 22087 Greensboro North Carolina 27420 Phone 336 547 5000 http www marconicommerce com Printed in the U S A MDE 3883 TRIND Retrofit Kits C00...

Отзывы: