MDE-3883 TRIND Retrofit Kits C00011-005
• 10/00
Page 15
The Advantage Series Installation
PRELIMINARY
FCC 11/30
The Advantage Series Installation
Preparing for Installation
1
Before proceeding read and follow all safety instructions and procedures.
2
Open main access doors. Refer to MDE-2531, Pump and Dispenser Start-Up/
Service Manual for access instructions.
3
Disconnect and remove existing hardware according to the following:
• For wide frame units disconnect any cables and remove any call or stop
buttons, or door alarm switch hardware from existing right options door. Save
all removed hardware for reassembly.
• For narrow frame units disconnect cables to PPU and main display.
4
Remove door mounting pin and right options door.
5
If unit has Cash Acceptor, remove door alarm and all hardware from old door and
save.
6
Dispose of door. Save pin for reassembly.
S0001719
Pin