7. The blinking cursor will highlight the options for the particular parameter you have selected. Use the
right/left arrow keys to select one of the options. Press the
ENTER
key to select the new option. A
brief message
Setup complete
will appear, indicating that the new option has been saved.
8. When you have finished modifying parameters, press the
ESC
key to go back to the
COM PORT
menu.
9. Press the
ESC
key again to go back to the
HMI SETUP
menu.
Changing the Contrast Setting
The contrast setting allows the OIT operator to optimize the contrast for the particular environment the OIT is installed in.
4
To change the contrast, perform the following:
1. Access the
LOCAL SETUP
menu per instructions given in the beginning of this chapter.
2. Press the
F4
key, or use the up/down arrow keys to move the blinking cursor to
4.HMI Setup
.
Press the
ENTER
key.
3. Use the up/down arrow keys to move the blinking cursor to
2.Contrast
. Then press the
ENTER
key.
4. From the
CONTRAST
menu, use the right/left arrow keys to vary the contrast setting of the LCD. The
contrast will change as you make adjustments.
5. When you have finished modifying the contrast, press the
ENTER
key to go back to the HMI Setup
menu. Press the
ESC
key to cancel any changes.
Changing the Back light Saver Setting
The backlight can also be controlled by the System Parameter Setting under the Global Settings menu. The backlight save
feature allows the OIT operator to control the LED backlight of the BLU300 LCD display. This feature can be used to
extend the lifespan of the display or minimize the distraction of the OIT when not in use. When configured, the BLU300
will shut off the LED backlight on the OIT display after a predefined time. The backlight is reactivated whenever any key on
the OIT is pressed.
*
The normal function of the key that is pressed will not be executed while the backlight is off.
4
To activate the backlight saver using the Local Setup menus:
1. Access the
LOCAL SETUP MENU
per instructions given in the beginning of this chapter.
2. Press the
F4
key, or use the up/down arrow keys to move the blinking cursor to
4.HMI Setup
.
Press the
ENTER
key.
3. Use the up/down arrow keys to move the blinking cursor to
3.Back light
.
Press the
ENTER
key.
4. From the
BACK LIGHT
menu, use the right/left arrow keys to switch between the two digits. Use the
function keys to change each digit value (ex. F1 =1, F5 =5, Shift F1 =6, Shift F10 =0). Range is 0 to
99 minutes. Note: if 0 is selected, the back light saver feature is disabled and the back light always
remains on.
5. When you have finished modifying the back light saver, press the
ENTER
key to go back to the HMI
Setup menu. Press the
ESC
key to cancel any changes.
Controlling the Backlight with the System Parameter Setting
One of the features of the System Parameter Setting is to call up screens on the OIT. The second feature of the System
Parameter Setting is control over the Backlight.
1010-0300, Rev 02
52
Blue Series Installation & Operation Manual