Write
attribute box, or click the PLC/Controller Address button
to display the Edit
PLC/Controller Address dialog box:
3. In the Reference Address area, click the pull-down box to select the
target PLC memory area
. Use the
numeric keypad to enter the specific
PLC memory address
. Select the
PLC Network Address
(if
applicable) and
HMI communications port
. Click
Enter
to go back to prior dialog box.
4. If you wish to read the contents of a different PLC register address, then check the
Read
checkbox and enter the PLC address you wish to display. Or click on the PLC/Controller Address
button
to display the Edit PLC/Controller Address dialog box. The BLU300 will then read
and display the contents of this register, but will still allow you to use a function key to display an
entry screen that allows you to write to the address listed in the
Write
attribute box.
*
If you wish to read the same PLC register as that to which you are writing, then leave the
Read
checkbox unchecked. It is not necessary to select the same address for the
Read
attribute, the
BLU300 will automatically assume that you wish to read the PLC register that is entered into the
Write
attribute box.
5. To initiate the process of writing a new value, you must assign a function key to the Numeric Input
object. Check the
Fun. Key
attribute box, then select a
function key
from the drop-down list box.
*
If you attempt to select a function key that has already been assigned to another Numeric Input
object on the same screen or a function key that has been assigned using the Local Function Key
Editor, an error message will be displayed notifying you that the key is currently being used.
6. In the
Format
attribute box, select the
format type
you wish to use. The options are:
Format
Range
Size
(Bits)
Description
Unsigned
0 to 65535
16
unsigned 16 bit format
0 to 4294967295
32
unsigned 32 bit format
Signed
-
32768 to +32767
16
signed 16 bit format
-2147483648 to +2147483647
32
signed 32 bit format
Hexadecimal
0000 to FFFF
16
hexadecimal 16 bit format
00000000 to FFFFFFFF
32
hexadecimal 32 bit format
BCD
0000 to 9999
16
BCD 16 bit format
00000000 to 99999999
32
BCD 32 bit format
Floating
-2147483648 to +2147483647
32 only
Floating 32 bit format
1010-0300, Rev 02
98
Blue Series Installation & Operation Manual
Содержание BLU300 Series
Страница 1: ......
Страница 64: ...1010 0300 Rev 02 62 Blue Series Installation Operation Manual...
Страница 113: ...1010 0300 Rev 02 112 Blue Series Installation Operation Manual...
Страница 138: ...Appendix B Dimensional Outlines Panel Cutout 1010 0300 Rev 02 Dimensional Outlines Panel Cutout 141...