HMI Setup Menu for the BLU300
The
HMI SETUP
menu allows you to change many of the hardware settings of the BLU300 OIT:
*
Most of the following settings can be changed through the
Tools...HMI
default settings. See
page 53 for more information on HMI Default Settings. Adjusting these settings from the local
setup menu is only provided as a convenient method of changing the parameters without
downloading a new project file.
Changing the Com Port Settings
The Com port setting on the OIT allows you to change the OIT’s communications parameters for the RS-232 and RS-485
ports without having to download a new project file from the BlueLeaf configuration software.
*
It is not necessary to adjust these settings in the local setup menu, since these settings are
automatically changed whenever you download a project from the BlueLeaf software into the
OIT. Adjusting these settings from the local setup menu is only provided as a convenient method
of changing the parameters without downloading a new project file.
4
To change these settings, perform the following:
1. Access the
LOCAL SETUP MENU
per instructions given in the beginning of this chapter.
2. Press the
F4
key, or use the up/down arrow keys to move the blinking cursor to
4.HMI Setup
.
Press the
ENTER
key.
3. Use the up/down arrow keys to move the blinking cursor to
1.Com port
.
Press the
ENTER
key.
4. There are three menu items:
•
HMI protocol
- used to change the OIT’s id #. This id # must match the
HMI Comm. Addr
setting
found in the BlueLeaf configuration software
Options…PC-HMI Comm Settings
menu before any
upload/download of a project file can take place. When transferring a project from one OIT to another,
the id #’s must match also.
•
RS232
- used to change the communications parameters for the RS-232 port (see table below).
•
RS485
- used to change the communications parameters for the RS-485/RS-422 port (see table below).
Parameter
Options
Baud Rate
4800, 9600, 19200, 38400, 57600, 115200
Data Bits
8 Bit, 7 Bit
Parity
Even, Odd, None
Stop Bit
1 Bit, 2 Bit
5. From the Com port menu, use the up/down arrow keys to move the blinking cursor to the target
selection: HMI protocol, RS-232, RS-485. Press the
ENTER
key.
6. To change a parameter (such a Baud Rate), use the up/down arrow keys to move the blinking cursor to
the parameter, and then press the
ENTER
key. At any time, you can cancel changing the parameter by
pressing the
ESC
key.
1010-0300, Rev 02
Basic Operation of the BLU300
51
Содержание BLU300 Series
Страница 1: ......
Страница 64: ...1010 0300 Rev 02 62 Blue Series Installation Operation Manual...
Страница 113: ...1010 0300 Rev 02 112 Blue Series Installation Operation Manual...
Страница 138: ...Appendix B Dimensional Outlines Panel Cutout 1010 0300 Rev 02 Dimensional Outlines Panel Cutout 141...