![Manitowoc QC0700 Скачать руководство пользователя страница 60](http://html.mh-extra.com/html/manitowoc/qc0700/qc0700_service-manual_701073060.webp)
Troubleshooting
Section 5
5-8
Part No. 80-1214-3
QF2200/QF2300
The evaporator and motor / gearbox are separate
assemblies. Warranty procedures require replacement
of the entire evaporator or motor /gearbox assembly.
Separate components are not available, and field
rebuilding during the warranty period is not allowed.
1. Disconnect power and water supply to the ice
machine and drain all water from the reservoir and
evaporator.
2. Remove reservoir retaining pin, water reservoir, ice
chute, and drain tubing (refer to Component
Removal).
3. Remove bolts securing foundation coupling to base.
4. Lift and support evaporator (evaporator weighs 80
lbs.).
5. Remove gear motor drip shield and disconnect line
voltage wiring at motor Molex connector.
6. Remove two screws holding motor speed sensor
and remove sensor.
7. Remove bolts securing gear motor assembly to
base.
8. Remove gear motor assembly from ice machine.
9. Remove coupling (use a 8 mm hex wrench for
coupling set screw), spline hub and keyway from
gear motor.
10. Apply anti-seize compound to the shaft and all bolts
to ease future disassembly.
3
SV3017
7
6
8
Revised 8/2003
Содержание QC0700
Страница 8: ...Table of Contents continued 6 Part No 80 1214 3 Revised 8 2003 ...
Страница 12: ...General Information Section 1 1 4 Part No 80 1214 3 THIS PAGE INTENTIONALLY LEFT BLANK Revised 8 2003 ...
Страница 30: ...Installation Instructions Section 2 2 18 Part No 80 1214 3 THIS PAGE INTENTIONALLY LEFT BLANK Revised 8 2003 ...
Страница 52: ...Ice Machine Sequence of Operation Section 4 4 4 Part No 80 1214 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 122: ...Electrical System Section 6 6 60 Part No 80 1214 3 THIS PAGE INTENTIONALLY LEFT BLANK Revised 8 2003 ...
Страница 144: ...Refrigeration System Section 7 7 22 Part No 80 1214 3 Using Pinch Off Tool SV1406 Revised 8 2003 ...
Страница 147: ...Revised 8 2003 ...
Страница 150: ...Refrigeration System Section 7 7 26 Part No 80 1214 3 THIS PAGE INTENTIONALLY LEFT BLANK Revised 8 2003 ...