![Manitowoc QC0700 Скачать руководство пользователя страница 133](http://html.mh-extra.com/html/manitowoc/qc0700/qc0700_service-manual_701073133.webp)
Section 7
Refrigeration System
Part No. 80-1214-3
7-11
Cycle Time/24 Hour Ice Production/Refrigerant Pressure Charts
These charts are used as guidelines to verify correct ice
machine operation. Accurate collection of data is
essential to obtain the correct diagnosis.
•
Refer to “Refrigeration System Diagnostics” for the
data that must be collected. This list includes: before
beginning service, ice production check, installation/
visual inspection, water system checklist, ice
formation pattern, safety limits, safeguards and
suction pressure analysis.
•
Ice production checks that are within 10% of the
chart are considered normal. This is due to variances
in water and air temperature. Actual temperatures
will seldom match the chart exactly.
•
Zero out manifold gauge set before obtaining
pressure readings to avoid misdiagnosis.
•
Discharge and suction pressure are highest at the
beginning of the cycle. Suction pressure will drop
throughout the cycle. Verify the pressures are within
the range indicated.
•
All pressure readings must be obtained at the ice
machine head section. Lineset length will affect
pressures at the condensing unit.
QF400 SELF-CONTAINED AIR COOLED
NOTE: These characteristics may vary depending on
operating conditions.
24 Hour Ice Production
Operating Pressures
Air Temp.
Entering
Condenser
°F/°C
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/ 21.1
395
360
335
80/26.7
375
320
300
90/32.2
335
300
270
100/37.8
295
250
240
110/43.3
255
230
225
Air Temp. Entering
Condenser °F/°C
Freeze Cycle
Discharge
Pressure PSIG
Suction
Pressure PSIG
50/10.0
160-180
27-29
70/21.1
210-235
32-35
80/26.7
250-295
34-39
90/32.2
285-315
37-41
100/37.8
320-360
40-46
110/43.3
370-405
44-49
Revised 8/2003
Содержание QC0700
Страница 8: ...Table of Contents continued 6 Part No 80 1214 3 Revised 8 2003 ...
Страница 12: ...General Information Section 1 1 4 Part No 80 1214 3 THIS PAGE INTENTIONALLY LEFT BLANK Revised 8 2003 ...
Страница 30: ...Installation Instructions Section 2 2 18 Part No 80 1214 3 THIS PAGE INTENTIONALLY LEFT BLANK Revised 8 2003 ...
Страница 52: ...Ice Machine Sequence of Operation Section 4 4 4 Part No 80 1214 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 122: ...Electrical System Section 6 6 60 Part No 80 1214 3 THIS PAGE INTENTIONALLY LEFT BLANK Revised 8 2003 ...
Страница 144: ...Refrigeration System Section 7 7 22 Part No 80 1214 3 Using Pinch Off Tool SV1406 Revised 8 2003 ...
Страница 147: ...Revised 8 2003 ...
Страница 150: ...Refrigeration System Section 7 7 26 Part No 80 1214 3 THIS PAGE INTENTIONALLY LEFT BLANK Revised 8 2003 ...