TEMPERATURE SENSOR
Function
The temperature sensor provides input to the control
board. The control board monitors the temperature
anytime the liquid line solenoid valve or compressor is
energized. When a temperature is sensed that is above
or below the correct temperature range, the ice machine
de-energizes.
Temperature Ranges:
QF400/QC700/QF800
155°F to 255°F (68°C to 124°C)
QF2200
30°F to 123°F
Specifications
10,000 Ohms at 77°F (25°C)
Check Procedure
The thermistor must be securely attached and insulated
to operate properly.
Verify that the thermistor resistance is accurate and
corresponding to the high and low temperature ranges.
1. Disconnect the thermistor at the control board.
Connect the ohmmeter to the isolated thermistor
wire leads.
2. Using a temperature meter capable of taking
readings on curved copper lines, attach the
temperature meter-sensing device to the
refrigeration line next to the thermistor.
3. With the ice machine running, verify that the
temperature of the refrigeration line (step 2)
corresponds to the thermistor resistance reading
(step 1) as stated in the temperature/resistance
chart.
TEMPERATURE/RESISTANCE CHART
As the temperature rises at the thermistor block, the
resistance drops.
!
Caution
Use only Manitowoc thermistors.
Important
Do not simply “insert” the sensing device under the
insulation. It must be attached to and reading the actual
temperature of the discharge line.
Important
If the ohmmeter reads “OL,” check the scale setting on
the meter before assuming the thermistor is bad.
Temperature of Thermistor
Resistance
K Ohms
(x 1000)
°C
°F
-17.77° – -12.22°
0° – 10°
85.35 – 62.46
-12.22° – -6.66°
10° – 20°
62.46 – 46.22
-6.66° – -1.11°
20° – 30°
46.22 – 34.56
-1.11° – 4.44°
30° – 40°
34.56 – 26.10
4.44° – 10.0°
40° – 50°
26.10 – 19.90
10.0° – 15.55°
50° – 60°
19.90 – 15.31
15.6° – 21.1°
60° – 70°
15.31 – 11.88
21.1° – 26.7°
70° – 80°
11.88 – 9.29
26.7° – 32.2°
80° – 90°
9.29 – 7.33
32.2° – 37.8°
90° – 100°
7.33 – 5.82
37.8° – 43.3°
100° – 110°
5.82 – 4.66
43.3° – 48.9°
110° – 120°
4.66 – 3.75
48.9° – 54.4°
120° – 130°
3.75 – 3.05
54.4° – 60.0°
130° – 140°
3.05 – 2.49
60.0° – 65.6°
140° – 150°
2.49 – 2.04
65.6° – 71.1°
150° – 160°
2.04 – 1.68
71.1° – 76.7°
160° – 170°
1.68 – 1.40
76.7° – 82.2°
170° – 180°
1.40 – 1.17
82.2° – 87.8°
180° – 190°
1.17 – 0.98
87.8° – 93.3°
190° – 200°
0.98 – 0.82
93.3° – 98.9°
200° – 210°
0.82 – 0.70
104.4° – 110.0°
220° – 230°
0.59 – 0.51
110.0° – 115.6°
230° – 240°
0.51 – 0.43
115.6° – 121.1°
240° – 250°
0.43 – 0.37
121.1° – 126.7°
250° – 260°
0.37 – 0.33
Revised 8/2003
Содержание QC0700
Страница 8: ...Table of Contents continued 6 Part No 80 1214 3 Revised 8 2003 ...
Страница 12: ...General Information Section 1 1 4 Part No 80 1214 3 THIS PAGE INTENTIONALLY LEFT BLANK Revised 8 2003 ...
Страница 30: ...Installation Instructions Section 2 2 18 Part No 80 1214 3 THIS PAGE INTENTIONALLY LEFT BLANK Revised 8 2003 ...
Страница 52: ...Ice Machine Sequence of Operation Section 4 4 4 Part No 80 1214 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 122: ...Electrical System Section 6 6 60 Part No 80 1214 3 THIS PAGE INTENTIONALLY LEFT BLANK Revised 8 2003 ...
Страница 144: ...Refrigeration System Section 7 7 22 Part No 80 1214 3 Using Pinch Off Tool SV1406 Revised 8 2003 ...
Страница 147: ...Revised 8 2003 ...
Страница 150: ...Refrigeration System Section 7 7 26 Part No 80 1214 3 THIS PAGE INTENTIONALLY LEFT BLANK Revised 8 2003 ...